Skip to main content
Iron Crest Remodel — Home
Deck Building Permits in Boise — Iron Crest Remodel

Deck Building Permits in Boise

A complete guide to permit requirements, setback codes, footing depth, railing regulations, inspection schedules, and fees for building a deck in Boise, Ada County, and the Treasure Valley.

Quick answer

In most cases, yes. Permit requirements vary by jurisdiction and project configuration, and we verify the applicable requirements during project planning. As a sourced example, the 2018 International Residential Code adopted in Idaho (Section R105.2) exempts only a freestanding deck that is 200 square feet or less, no more than 30 inches above grade at any point, not attached to the dwelling, and not serving the required exit door.

When You Need a Deck Permit in Boise

Not every deck project in Boise requires a building permit. The requirement depends on the deck's size, height above grade, and how it connects to your home, and thresholds vary by jurisdiction; we verify the applicable requirements during project planning. The categories below follow the 2018 IRC exemption (Section R105.2) as adopted in Idaho.

Requires a Permit

Decks over 200 square feet in area

The IRC R105.2 exemption applies only to decks of 200 square feet or less, so a larger deck generally requires a building permit from the City of Boise or Ada County Development Services, regardless of height above grade.

Decks over 30 inches above finished grade

A deck surface more than 30 inches above the surrounding finished grade at any point falls outside the IRC R105.2 exemption and generally requires a building permit. The same 30-inch threshold triggers guard requirements under IRC R312.1.1.

Decks attached to the house (ledger board connection)

A deck structurally attached to the home through a ledger board is not exempt under IRC R105.2 and generally requires a permit. Ledger connections are a critical structural detail governed by IRC R507.9.

Decks with a roof structure or pergola

Adding a solid roof, pergola, shade structure, or any overhead covering to a deck generally requires a building permit. These structures add wind and snow load considerations and may affect setback compliance.

Multi-level or elevated deck structures

Decks with multiple levels, second-story decks, and tall elevated decks require a building permit and may require engineered drawings depending on the jurisdiction and configuration. Lateral bracing requirements increase with height.

Decks with electrical, plumbing, or gas connections

Installing deck lighting, electrical outlets, outdoor kitchens, gas fire pits, or plumbing for an outdoor sink generally requires separate trade permits (electrical, plumbing, gas) in addition to the building permit.

Generally Permit-Exempt

Ground-level decks under 200 sq ft and under 30" above grade

Under IRC R105.2, a freestanding platform deck that does not exceed 200 square feet in area, sits no more than 30 inches above finished grade at any point, is not attached to the dwelling, and does not serve the required exit door is generally exempt from permit requirements; local jurisdictions may amend this.

Freestanding floating decks on grade

Decks placed directly on the ground or on concrete deck blocks without excavated footings, provided they meet the size and height thresholds. These are often called floating decks or platform decks.

Deck surface replacement (same footprint)

Replacing existing deck boards with new decking material (composite, wood, PVC) on the same structural frame without modifying the framing, footings, or overall footprint.

Deck staining, sealing, or painting

Applying finish treatments to an existing deck. Cosmetic maintenance and preservation work does not require permits.

Replacing railing with code-compliant railing

Swapping damaged or deteriorated railing for new railing in the same location, provided the new railing meets current code requirements (height, baluster spacing, structural capacity).

Minor repairs to existing deck structure

Replacing individual damaged joists, boards, or posts on an existing deck without altering the overall structure, size, or configuration. Extensive structural repairs may still require a permit.

Important note: Even permit-exempt decks must comply with all applicable setback requirements and zoning regulations. Building a deck in a setback area or easement can result in a required removal order regardless of permit status. When in doubt, contact the City of Boise Planning & Development Services at (208) 384-3830 or Ada County Development Services at (208) 287-7900 before starting work.

Deck Permit Application Process

The deck permit process in Boise and Ada County follows a structured sequence. Whether your property is within Boise city limits, in unincorporated Ada County, or in surrounding communities like Meridian, Eagle, Star, or Garden City, the general process is similar. Iron Crest Remodel manages every step of this process for our clients.

1

Prepare Site Plan & Construction Drawings

The first step is preparing a site plan that shows the proposed deck location relative to your property lines, the house, and any easements or setbacks. The site plan must clearly indicate all dimensions and distances to property boundaries.

Construction drawings must include: Deck dimensions and layout, footing locations and sizes, post sizes and heights, beam spans and sizes, joist spacing and spans, ledger board connection detail (if attached), railing design and dimensions, stairway layout, and materials specifications. For complex or elevated decks, a licensed engineer may need to prepare or stamp the structural drawings.

2

Submit Permit Application

Submit the completed application along with the site plan, construction drawings, and any required engineering documents to the appropriate jurisdiction. Applications can be submitted online through the City of Boise's ePermit portal or Ada County's online permitting system.

Required with submission: Completed application form, site plan with setback dimensions, construction plans, materials list, contractor's license number, proof of insurance, and the application fee. If the deck is near a property line or in a special overlay zone, additional documentation may be required.

3

Plan Review

A plan reviewer examines the submitted documents for compliance with the International Residential Code (IRC) Section R507 (Decks) as adopted by the State of Idaho and local amendments. The review covers structural adequacy, setback compliance, footing depth and sizing, railing requirements, and stairway code compliance.

If the reviewer identifies deficiencies or requires additional information, you will receive a corrections letter. Responding promptly with the requested changes avoids delays. Incomplete initial submissions are the most common cause of extended review timelines.

4

Permit Issuance & Construction

Once plans are approved, the permit is issued and construction can begin. The permit card must be posted at the job site in a location visible from the street. Under the IRC as adopted (Section R105.5), a permit becomes invalid if work does not begin within 180 days of issuance; jurisdictions may set their own periods, and extensions are generally available upon request before expiration.

Building permit fees: Set by each jurisdiction's adopted fee schedule, generally based on project valuation, with plan review charged separately. Fees vary by parcel, jurisdiction, and project configuration; we confirm the current schedule during project planning.

Additional trade permits: Electrical permits for deck lighting and outlets. Plumbing permits for outdoor kitchens or sinks. Gas permits for fire pits or built-in grills. Each trade permit requires its own application and inspections.

Setback Requirements for Decks in Boise

Setbacks define the minimum distance a structure must be from your property lines. Deck setbacks vary by parcel, zoning district, deck type (open vs. covered), and the specific property line (front, side, rear); we verify the applicable requirements during project planning. Violating setback requirements can result in a stop-work order, required removal, or denial of a certificate of completion.

Front, side, and rear setbacks are set by the zoning district in the City of Boise's Modern Zoning Code (or Ada County's code for unincorporated parcels), and they are further modified by plat conditions, easements, overlay zones, and whether the deck is open or covered. Requirements vary by parcel, zoning district, and project configuration; we verify the applicable requirements during project planning rather than relying on a generic table.

Open Deck Setback Exceptions

Open decks (no roof, walls, or solid overhead covering) may be allowed to project into the rear setback in some residential zones, subject to a minimum clearance from the rear property line. Whether an exception applies, and how far it extends, depends on the zoning district and the parcel.

  • Open deck with no roof structure qualifies
  • A minimum rear property line clearance still applies
  • Exceptions may not apply to corner lots or street-side setbacks
  • Verify with your specific zoning district before relying on this exception

Covered Deck & Pergola Setbacks

Covered decks, pergolas with solid or louvered roofing, and any deck with a roof structure are generally treated as part of the main building for setback purposes. This means they must meet the full setback requirements for the primary structure, without the open-deck projection exception.

  • Solid-roof covered decks follow main structure setbacks
  • Pergolas with substantial roof coverage may be classified as covered structures
  • Roof overhangs may be allowed a limited projection into the setback, depending on the zone
  • Converting an open deck to covered may require a variance if in the setback zone

How to Find Your Property's Specific Setbacks

Setbacks vary not only by zoning district but also by specific plat conditions, planned unit developments (PUDs), and overlay zones. To determine the exact setbacks for your property, use one of these methods.

City of Boise GIS Map

Use the City of Boise's online GIS mapping tool to look up your parcel's zoning classification, which determines the baseline setback requirements.

Plat Map & CC&Rs

Review your subdivision plat map for any specific setback conditions, building envelopes, or easements that override standard zoning setbacks.

Planning & Zoning Office

Contact Boise Planning & Zoning at (208) 384-3830 for a definitive determination of setbacks applicable to your specific parcel and proposed deck project.

Footing & Foundation Code Requirements

Deck footings are the foundation of the entire structure. In Boise and Ada County, footing requirements are driven by frost depth, soil conditions, and the loads transferred from the deck above. Getting footings right is critical because they are the first thing inspected and the most expensive element to correct after the fact.

Frost Line & Footing Depth

The City of Boise and Ada County design criteria set a minimum frost depth of 24 inches, and deck footings must extend below the frost line to prevent frost heave. Canyon County and each city publish their own criteria, which we confirm at permit time. Frost heave occurs when moisture in the soil freezes and expands, lifting footings that are not deep enough. This can cause the entire deck to shift, crack, or separate from the house.

Minimum footing depth: 24 inches (City of Boise / Ada County criteria)

Measured from the finished grade at the footing location to the bottom of the footing. If the grade varies, each footing must independently reach frost depth below the grade at its specific location.

Footing diameter sized to the load

Sono tubes for residential deck footings are commonly 12 inches in diameter. Larger footings (16" or 18") may be required for beams carrying longer spans or heavier loads such as hot tubs.

Concrete strength per IRC Table R402.2

IRC Table R402.2 sets a 2,500 PSI baseline compressive strength, with higher strength and air entrainment where concrete is exposed to weather. Most ready-mix suppliers deliver 3,000 PSI or higher.

Footing must bear on undisturbed soil

The bottom of the footing must rest on native, undisturbed soil. If the hole is over-excavated, the footing must extend deeper to reach undisturbed bearing soil or the disturbed soil must be compacted as the inspector directs.

Footing Types for Boise Decks

Sono Tube (Cardboard Form) Footings

The most common footing type for residential decks in Boise. A cylindrical cardboard form is placed in the excavated hole, and concrete is poured into the tube. A post anchor bracket (such as Simpson ABU or CB series) is set into the wet concrete or attached after curing using an epoxy anchor.

Typical sizes: 12" diameter for standard posts, 16" or 18" for heavy-load locations. Cost: $15 to $40 per footing for materials.

Poured Concrete Pad Footings

A larger concrete pad poured at the base of the excavated hole, often with a sono tube column above. The wider pad distributes the load over a larger soil area, useful when soil bearing capacity is a concern or for heavy-load applications.

Typical use: Hot tub support, multi-level decks, or sites with softer soil conditions common in some Boise neighborhoods near the river or canal systems.

Helical Pier Footings

A steel shaft with helical plates that is mechanically screwed into the ground using hydraulic equipment. Helical piers bypass problem soils and reach stable bearing strata below. They are an alternative to traditional poured footings, especially useful in areas with expansive clay soils or high water tables.

Advantages: No concrete curing time, immediate load capacity, removable and reusable. Cost: $150 to $350 per pier installed. Often used for hillside deck construction in the Boise foothills.

Boise soil conditions: Much of the Boise metro area has clay and silt soils; IRC Table R401.4.1 assigns presumptive bearing values by soil class unless a site-specific report says otherwise. Areas near the Boise River, canals, and lower elevations may have softer alluvial soils requiring larger footings or helical piers. A geotechnical report may be required for decks on steep slopes or in areas with known soil issues.

Structural Code Requirements for Decks

Deck structural requirements in Boise follow the International Residential Code (IRC) Section R507, as adopted by the State of Idaho. These requirements govern every structural element from the ledger board to the railing posts. The ground snow load in the City of Boise design criteria adds an important design factor for covered decks and any structure that can accumulate snow; each jurisdiction publishes its own figure.

Joist Requirements

Deck joists must be sized according to IRC R507 span tables, which account for joist species, grade, spacing, and the design loads (40 PSF live load plus 10 PSF dead load for residential decks, plus snow load where applicable).

  • Allowable spans come from IRC Table R507.6 for the species, grade, and spacing
  • Wider joist spacing or a lower grade shortens the allowable span
  • Cantilevers are limited to a fraction of the back span per R507.6
  • Joist hangers required at beam and ledger connections

Beam Requirements

Beams support the joists and transfer loads to the posts and footings. Beam sizing depends on the span between posts, the joist span (tributary area), and the total design load including Boise's snow load.

  • Allowable beam spans come from IRC Table R507.5 by beam size and joist span
  • Longer joist spans (more tributary load) shorten the allowable beam span
  • Built-up beams must be fastened per R507.5 to act as one member
  • Beam-to-post connections require approved hardware

Post & Bracing Requirements

Posts transfer beam loads to the footings. Post sizing depends on height, load, and species. Lateral bracing prevents the deck from racking (side-to-side movement) and is critical for elevated decks.

  • Post size and maximum height come from IRC Table R507.4
  • 6x6 posts are the common choice for elevated decks and heavy loads
  • Posts must not be notched more than 50% of their dimension
  • Lateral bracing required per IRC R507.9.2

Ledger Board Attachment Requirements

The ledger board is the most critical connection point on an attached deck. It transfers half of the deck's total load to the house structure. Ledger board failures are the number-one cause of deck collapses nationwide. Boise building inspectors scrutinize this connection closely during both framing and final inspections.

Fastener Requirements

  • 1/2" diameter lag screws or through-bolts into the house rim joist (IRC R507.9.1.3)
  • Staggered top and bottom rows at the spacing in IRC Table R507.9.1.3
  • Edge and end distances per IRC Figure R507.9.1.3(1)
  • Through-bolts preferred over lag screws for long-term reliability

Flashing Requirements

  • Metal Z-flashing required above the ledger board
  • Flashing must tuck under the house siding or weather barrier
  • Self-adhering membrane behind the ledger as a secondary barrier
  • Improper flashing is the most common cause of ledger rot and failure

Snow load design: The ground snow load is published in each jurisdiction's design criteria (the City of Boise and Ada County publish theirs; Canyon County and each city publish their own). It is considered alongside the 40 PSF live load and 10 PSF dead load when designing covered decks, pergolas, and any deck structure that can accumulate snow. Higher elevations in the Boise foothills may be subject to higher ground snow loads.

Railing & Stairway Code Requirements

Railing and stairway codes exist to prevent falls, which are the most common deck-related injury. These requirements are strictly enforced during deck inspections in Boise and are among the most frequent causes of inspection failures when not correctly implemented.

Deck Railing Requirements

Guard required above 30" (IRC R312.1.1)

Under the 2018 IRC (R312.1.1), any walking surface more than 30 inches above grade within 36 inches horizontally must have a guard along the open sides. This is the same threshold used in the IRC permit exemption.

Minimum guard height: 36 inches (IRC R312.1.2)

Guards on residential decks must be a minimum of 36 inches high, measured from the deck surface to the top of the guard. Commercial or public decks fall under the IBC, which requires 42 inches.

Baluster spacing: 4-inch sphere rule (IRC R312.1.3)

The space between balusters (pickets) must not allow passage of a 4-inch sphere at any point. This is commonly called the "sphere test" and prevents children from getting their heads through the railing.

Structural load capacity: 200 lbs concentrated (IRC Table R301.5)

Guard railings must resist a 200-pound concentrated load applied in any direction at the top of the railing. This ensures the railing can withstand someone leaning or falling against it.

No climbable elements

Railing designs must not include horizontal elements or patterns that create a ladder effect, allowing children to climb the railing. Horizontal cable and wire railings must maintain the 4-inch sphere test and are subject to additional review.

Bottom rail clearance

The space between the deck surface and the bottom rail or lowest baluster must not exceed 4 inches. A 4-inch sphere must not pass through the space between the deck and the bottom of the railing system.

Stairway Requirements

Minimum stair width: 36 inches (IRC R311.7.1)

Deck stairs must be at least 36 inches wide, measured between the inside faces of the stair stringers. This provides adequate passage width for safe use.

Riser height: 7-3/4 inches maximum (IRC R311.7.5.1)

Each stair riser must not exceed 7-3/4 inches in height. The variation between the tallest and shortest riser in a single flight must not exceed 3/8 inch.

Tread depth: 10 inches minimum (IRC R311.7.5.2)

Each stair tread must have a minimum depth of 10 inches, measured from the front edge (nosing) of one tread to the front edge of the next. This provides adequate foot placement for safe descent.

Graspable handrail required (IRC R311.7.8)

Stairs with four or more risers must have a graspable handrail on at least one side. The handrail must be between 34 and 38 inches high, measured from the stair nosing. The handrail profile must be graspable with a cross-section of 1-1/4" to 2" diameter or equivalent.

Stairway lighting

Exterior stairs serving deck areas used at night must have adequate lighting at the top and bottom landings. While specific illumination levels are not always specified for residential, functional lighting is required and inspectors will verify its presence.

Landing requirements (IRC R311.7.6)

A landing is required at the top and bottom of each stairway. The landing must be at least as wide as the stairs and a minimum of 36 inches in the direction of travel. The deck surface itself typically serves as the top landing.

Code-compliant deck railing with proper baluster spacing and graspable handrail in Boise

Inspection Schedule for Deck Construction

Deck construction in Boise requires multiple inspections at specific stages. Each inspection must pass before work can proceed to the next phase. Iron Crest Remodel schedules all inspections and meets with the inspector on-site so you never need to coordinate with the building department directly.

1

Footing Inspection

Conducted after holes are excavated and forms are placed, but before concrete is poured. The inspector verifies footing depth, diameter, location, and soil conditions.

What the Inspector Checks:

  • Footing depth reaches the frost depth on the approved plans (24" under City of Boise / Ada County criteria)
  • Footing diameter matches approved plans
  • Footing locations match the site plan
  • Soil at the bottom is undisturbed native soil
  • No standing water in the footing holes

Common failure: Footings not reaching the required frost depth. If the soil is rocky and digging is difficult, the inspector may require photo documentation or alternative verification that the frost line depth has been achieved.

2

Framing Inspection

Conducted after the deck framing (posts, beams, joists, ledger, and railing posts) is complete but before the decking surface is installed. This is the most comprehensive structural inspection for a deck project.

What the Inspector Checks:

  • Post-to-footing connections (anchor hardware)
  • Beam-to-post connections (through-bolts or approved hardware)
  • Joist hangers at all joist-to-beam and joist-to-ledger connections
  • Ledger board fasteners, spacing, and flashing
  • Lateral bracing installation
  • Lumber species, grade, and treatment verification
  • Railing post attachment to the deck frame

Common failure: Missing or incorrect joist hangers, insufficient ledger fasteners, and missing flashing behind the ledger board. Ensuring all hardware is installed before calling for this inspection avoids delays.

3

Final Inspection

Conducted after the deck is fully completed, including decking surface, railings, stairs, and any lighting. This is the last inspection before the permit is closed and a certificate of completion is issued.

What the Inspector Checks:

  • Guard height (36" minimum residential, IRC R312.1.2)
  • Baluster spacing (4" sphere test)
  • Stair riser height and tread depth consistency
  • Graspable handrail on stairs (if 4+ risers)
  • Overall construction matches approved plans
  • Electrical inspection (if deck lighting/outlets installed)
  • Permit card posted and visible at job site

Common failure: Railing baluster spacing exceeding 4 inches, stair riser height inconsistency greater than 3/8 inch, and missing graspable handrail on stairs. These are easy to get right with proper planning and attention during installation.

Special Considerations for Boise Decks

Boise's unique geography, climate, and development patterns create special considerations for deck construction that go beyond standard building codes. The following situations require additional planning, permits, or engineering that should be addressed early in the design process.

Hillside & Slope Decks

Many homes in the Boise foothills, North End, and East Boise are built on sloping lots. Decks on slopes present unique structural challenges including taller posts, increased lateral loads, and potential soil stability concerns. Tall posts are sized from IRC Table R507.4 and typically call for 6x6 lumber and additional lateral bracing or cross-bracing.

Additional requirements: Steep slopes may require a geotechnical report. Engineered drawings are commonly required for tall elevated decks. Erosion control measures may be required during construction. Requirements vary by parcel and jurisdiction; we verify them during project planning.

Waterfront & Canal Setbacks

Properties adjacent to the Boise River, irrigation canals, or drainage channels are subject to additional setback requirements beyond standard zoning setbacks. Riparian setbacks protect waterways and may be regulated by the City of Boise, the Army Corps of Engineers, or irrigation districts such as the New York Canal or Ridenbaugh Canal.

Waterfront setbacks and canal easements: Riparian setbacks from the Boise River and irrigation-district easements along canals vary by parcel and by the governing agency. These are typically not subject to a zoning variance, so we verify them before design.

HOA Restrictions

Many Boise-area subdivisions have homeowner association (HOA) covenants that impose additional restrictions on deck construction beyond what the building code requires. HOA restrictions may limit deck size, height, materials, colors, railing styles, and even the type of decking material allowed.

Important: HOA approval is separate from the building permit and must typically be obtained before submitting the permit application. Some HOAs require architectural review committee approval, which can add several weeks to the project timeline. Review your CC&Rs before finalizing deck plans.

Hot Tub Structural Requirements

A filled hot tub weighs between 3,000 and 6,000 pounds depending on size. Standard deck framing is not designed for this concentrated load. If you plan to place a hot tub on your deck, the area beneath the hot tub must be specifically engineered with reinforced framing, closer joist spacing, larger beams, and potentially additional footings.

Design requirements: The hot tub area is engineered for the actual filled weight, well above the standard 40 PSF deck live load. Doubled or tripled joists under the hot tub. Additional beam and footing support. Electrical permit required for hot tub wiring (240V dedicated circuit with GFCI protection).

Covered Deck vs. Pergola Code Differences

The distinction between a covered deck (solid roof) and a pergola (open lattice or slat roof) affects setback requirements, snow load design, and permit classification. A solid-roof covered deck is treated as an addition to the home for setback and code purposes. An open pergola may receive different treatment depending on the percentage of coverage.

Key distinction: Open-lattice pergolas may be treated differently for snow load and setback purposes in some zones; the thresholds vary by jurisdiction. Pergolas with solid or near-solid coverage (louvered systems, polycarbonate panels) are generally treated as covered structures and must meet full snow load and setback requirements.

Electrical Permits for Deck Features

Electrical work on or for a deck generally requires a separate electrical permit. This includes low-voltage deck lighting, standard-voltage outlets, hot tub wiring, outdoor kitchen appliance circuits, and audio/entertainment system wiring. All outdoor electrical work must be performed with weather-rated materials and proper GFCI protection.

GFCI requirement: All exterior outlets and circuits serving the deck area must be GFCI-protected. Hot tubs require a dedicated 240V circuit with a disconnect switch located within sight of the tub but at least 5 feet from the water's edge. Outdoor lighting circuits must be on a separate circuit from general-purpose outlet circuits.

Elevated deck construction on a sloped lot in the Boise foothills with mountain views

Frequently Asked Questions

Common questions about deck building permits, codes, and regulations in the Boise area.

Do I need a permit to build a deck in Boise?

In most cases, yes. Permit requirements vary by jurisdiction and project configuration, and we verify the applicable requirements during project planning. As a sourced example, the 2018 International Residential Code adopted in Idaho (Section R105.2) exempts only a freestanding deck that is 200 square feet or less, no more than 30 inches above grade at any point, not attached to the dwelling, and not serving the required exit door. Attached decks, elevated decks, and decks with a roof structure or pergola generally need a permit, and even exempt decks must still comply with zoning setbacks.

How much does a deck permit cost in Boise?

Deck permit fees are set by each jurisdiction's adopted fee schedule and are generally based on project valuation, with plan review charged separately. If electrical work is included for deck lighting or outlets, a separate electrical permit is required. Fees vary by parcel, jurisdiction, and project configuration; we confirm the current fee schedule during project planning and include permit costs in your estimate.

How deep do deck footings need to be in Boise?

Deck footings must extend below the local frost line. The City of Boise and Ada County design criteria set a minimum frost depth of 24 inches; Canyon County and each city publish their own criteria, which we confirm at permit time. Footings that do not reach the frost line are subject to frost heave, which can lift and damage the deck structure. Sono tubes or poured footings are sized to the load they carry on the approved plans.

What are the setback requirements for decks in Boise?

Setback requirements vary by parcel, zoning district, and project configuration; we verify the applicable requirements during project planning. In general, open decks without a roof are treated differently from covered decks, pergolas, and roofed structures, which are usually held to the setbacks for the main structure. The City of Boise Planning & Development Services or Ada County Development Services can confirm the setbacks for your specific parcel.

How long does it take to get a deck permit approved in Boise?

Review times vary by jurisdiction, season, and project complexity. Simple, straightforward deck plans with complete documentation tend to be reviewed faster, while complex designs (multi-level decks, hillside construction, or unusual structural configurations) may require additional review time. Incomplete submissions that require corrections or additional information add review cycles. Iron Crest Remodel prepares complete permit packages to minimize review cycles.

Does Iron Crest Remodel handle the deck permit process?

Yes. We manage the entire deck permit process as part of our deck building service. This includes preparing construction drawings and site plans, calculating structural loads, submitting the permit application, paying all permit fees (included in your project cost), scheduling every required inspection, and meeting with inspectors on-site. You do not need to visit the permit office, create drawings, or coordinate any inspections yourself.

We Handle All Deck Permits for You

Iron Crest Remodel manages the entire permit process as part of your deck building project. From site plans and construction drawings to application submission, plan review coordination, and every required inspection, you never have to visit the permit office.